Inverter 60HzJP/GW-26BPC-60HZ
EER 2.78DC inverter split for a single small room in a 60Hz market.
- Capacity
- 9,000 BTU
- Room size
- 10 to 17 m²
Choose a category, then compare capacity, efficiency, noise, dimensions, pipe sizes and loading figures across models in one table.
Inverter split systems for North American 60Hz markets. Cooling only, with an inverter compressor that holds a steady temperature.
Inverter 60HzDC inverter split for a single small room in a 60Hz market.
Inverter 60HzDC inverter split for a bedroom in a 60Hz market.
Inverter 60HzDC inverter split for a living room or small office in a 60Hz market.
Inverter 60HzDC inverter split for open plan floors in a 60Hz market.
4 models in this category. Scroll sideways on smaller screens to compare every model.
| Specification | JP/GW-26BPC-60HZ | JP/GW-35BPC-60HZ | JP/GW-50BPC-60HZ | JP/GW-70BPC-60HZ |
|---|---|---|---|---|
| Model | JP/GW-26BPC-60HZ | JP/GW-35BPC-60HZ | JP/GW-50BPC-60HZ | JP/GW-70BPC-60HZ |
| Power supply | 1Ph / 220-240V / 60Hz | 1Ph / 220-240V / 60Hz | 1Ph / 220-240V / 60Hz | 1Ph / 220-240V / 60Hz |
| Cooling capacity | 9,000 BTU/h (2,500 W) | 12,000 BTU/h (3,200 W) | 18,000 BTU/h (4,800 W) | 24,000 BTU/h (6,810 W) |
| Cooling input | 900 W | 1,180 W | 1,780 W | 2,350 W |
| Cooling rated current | 4.0 A | 5.3 A | 7.9 A | 10.5 A |
| Energy efficiency | EER 2.78 | EER 2.71 | EER 2.70 | EER 2.90 |
| Max. input consumption | 1,600 W | 1,720 W | 2,520 W | 3,100 W |
| Max. current | 8.50 A | 9.00 A | 13.00 A | 14.80 A |
| Compressor | Rotary, GMCC / GREE | Rotary, GMCC | Rotary, HIGHLY | Rotary, GMCC |
| Indoor air flow (Turbo/Hi/Mi/Lo) | 500 / 450 / 370 / 320 m³/h | 550 / 500 / 450 / 370 m³/h | 850 / 750 / 650 / 580 m³/h | 1,050 / 950 / 800 / 680 m³/h |
| Indoor noise (Turbo/Hi/Mi/Lo) | 39 / 34 / 32 / 30 dB(A) | 42 / 39 / 36 / 33 dB(A) | 45 / 42 / 39 / 37 dB(A) | 49 / 47 / 45 / 42 dB(A) |
| Indoor unit dimension (W x H x D) | 695 x 275 x 190 mm | 780 x 275 x 190 mm | 910 x 295 x 205 mm | 1,030 x 360 x 248 mm |
| Indoor net weight | 6 kg | 6.5 kg | 10 kg | 13 kg |
| Outdoor noise | 50 dB(A) | 52 dB(A) | 55 dB(A) | 59 dB(A) |
| Outdoor unit dimension (W x D x H) | 610 x 295 x 495 mm | 710 x 295 x 495 mm | 760 x 305 x 550 mm | 780 x 350 x 600 mm |
| Outdoor net weight | 17 kg | 19 kg | 24 kg | 30 kg |
| Refrigerant | R410A | R410A | R410A | R410A |
| Pipe connection (liquid / gas) | Liquid Φ6 mm / Gas Φ9 mm | Liquid Φ6 mm / Gas Φ9 mm | Liquid Φ6 mm / Gas Φ12 mm | Liquid Φ6 mm / Gas Φ12 mm |
| Max. refrigerant pipe length | 10 m | 10 m | 10 m | 15 m |
| Max. difference in level | 5 m | 5 m | 5 m | 10 m |
| Operating temperature range | 16°C to 43°C | 16°C to 43°C | 16°C to 43°C | 16°C to 43°C |
| Ambient temperature range | 16°C to 48°C | 16°C to 48°C | 16°C to 48°C | 16°C to 48°C |
| Recommended room area | 10 to 17 m² | 13 to 27 m² | 20 to 40 m² | 30 to 55 m² |
| Loading (40ft HQ / 20ft) | 360 / 167 | 334 / 143 | 267 / - | 184 / - |